About

Chendura is a Company integrating the research and development, sales and after-sales of diesel engines, diesel generator sets and water pump sets. It specializes in providing various diesel engine complete machines and diesel engine accessories.

Read More

Gallery

  • anna@chendura.com

Perkins 50KW mute generator set 50/60HZ four-protection ATS optional

Perkins 50KW mute generator set 50/60HZ four-protection ATS optional

Category Item Specifications/Details Product Identification Model Numbers 1104D-44TG2, 1104D-44TG3 Series 1100 Series   Product...


Keywords Perkins, Perkins generator, diesel generator, silent generator, generator set

Email Now

anna@chendura.com

Call Us / Whatsapp

+8613884816171


Perkins 50KW mute generator set 50/60HZ four-protection ATS optional

Category Item Specifications/Details
Product Identification Model Numbers 1104D-44TG2, 1104D-44TG3
Series 1100 Series  
Product Name Electropak  
Gross Power 56.6 - 69.0 kWm @ 1500/1800 rpm  
Basic Technical Data Cylinders & Arrangement 4 (Vertical inline)
Cycle Four-stroke  
Fuel Type Diesel  
Induction/Combustion System Turbocharged + Direct injection  
Compression Ratio 18.23:1  
Bore/Stroke 105.0 mm / 127.0 mm  
Cubic Capacity 4.4 litres  
Rotation Direction • Anti-clockwise (flywheel view)  
• Clockwise (front view)    
Firing Order (Cyl.1 = furthest from flywheel) 1, 3, 4, 2  
Est. Weight (Dry/Wet) 401 kg / TBA kg  
Overall Dimensions Length (Radiator → Air Cleaner Rear) 1239 mm
Width 615 mm  
Height (w/ Radiator Brackets) 951 mm  
Moments of Inertia (mk²) Engine Rotational Inertia 0.1402 kgm² (excl. pulley/flywheel)
Crank Pulley Inertia Refer to ESM (option-dependent)  
Flywheel Inertia 1.14 kgm² (option-dependent)  
Centre of Gravity (Wet) Forward from Block Rear 227.2 mm
Above Crankshaft Centre Line 160.4 mm  
Offset to RHS of Crankshaft Line 8.1 mm  
Performance Reference Standard ISO 3046-1:2002
Rating Tolerance 5%  
Speed Variation (Constant Load) G2/G3: +0.75%  
Test Conditions Air Temp/Barometric Pressure 25°C / 100 kPa
Relative Humidity 30%  
Air Inlet/Exhaust Back Pressure 3 kPa / 12 kPa  
Fuel Temp (Inlet Pump) 40°C  
Sound Level & Emissions Average Sound Pressure Level 104.5 dBA (A)
Sound Level Note Adjustments needed for non-test ambient conditions (contact Perkins Tech Service)  
Emissions Certification Compliant with EU 2011/98/EC Stage IIa